Free delivery on orders over AED 100 across the UAE*
Dwyer Submersible Level Transmitter, SBLT2-5-40, 10-30VDC, 5 Psi, 4-20mA, 12.2 Mtrs Cable Length
Dwyer

Dwyer Submersible Level Transmitter, SBLT2-5-40, 10-30VDC, 5 Psi, 4-20mA, 12.2 Mtrs Cable Length

SV Code: 866419123146Model No.: SBLT2-5-40
13-30 VDC4-20 mA5 psi50 ms
AED 4,550.00/ Piece
Price includes VAT· Sign in to see your account priceMore Details
Out of stock
Return or exchange within 30 days of delivery.Sign in to see your account price and place orders.

Key features

  • Loop Resistance: 900 ohm at 30 VDC max
  • Wetted Materials: 316 SS, 316L SS, epoxy adhesive; Cable: Polyether polyurethane; Bullet Nose: PVC
  • Mounting: Suspended in tank below level being measured
  • Protection: Lightning and surge protection utilizing dual arrestor technology
  • Slim Design with Bullet Nose: Protects the diaphragm from damage and allows installation in tight spaces
  • Lightning and Surge Protection: Dual arrestor technology grounded to the case eliminates power supply surges and lightning ground strike transients
Full description & specifications ↓
Fast delivery Genuine & warranty Bulk quotes

Specifications

SV Code866419123146
BrandDwyer
CategorySubmersible Level Transmitters
UnitPiece
Power Supply13-30 VDC
Output Current4-20 mA
Accuracy+/-0.25 Percent
Maximum Pressure5 psi
Cable Length12.2 Mtr
Operating Temperature-18 to 66 Deg.C
Response Time50 ms
DeliveryNot on the shelf right now; 7 working days to source and deliver.

Description

The Dwyer SBLT2-5-40 is a submersible level transmitter designed for accurate liquid level measurement in various applications, including groundwater monitoring, environmental remediation, and water tanks.

Features

  • Loop Resistance: 900 ohm at 30 VDC max
  • Wetted Materials: 316 SS, 316L SS, epoxy adhesive; Cable: Polyether polyurethane; Bullet Nose: PVC
  • Mounting: Suspended in tank below level being measured
  • Protection: Lightning and surge protection utilizing dual arrestor technology
  • Slim Design with Bullet Nose: Protects the diaphragm from damage and allows installation in tight spaces
  • Lightning and Surge Protection: Dual arrestor technology grounded to the case eliminates power supply surges and lightning ground strike transients
  • Maintenance-Free Filter: Prevents particulate or water droplets from entering the transducer
  • Durable Cable: 270 lb tensile strength shielded and vented cable with excellent chemical compatibility